2030 HF SBB Transceiver

2030- Rugged commercial grade HF transceiver

- 1.6 MHz to 30 MHz, all mode, 125 W PEP
RF power output

- 30 programmable channels and Selcall fitted as standard

- Rapid mobile or base station installation

- Intuitive "ease of use" operation

- Telcall and voice security options


The Barrett 2030 HF transceiver is an addition to Barrett's proven range of HF transceivers for customers that don't require some of the more advanced features offered by the 2050 transceiver.

 

Configuration Examples

2030 configuration exsample

 

General Specification

Standards Exceeds/complies with Australian/ New Zealand standard AS/NZS 4770:2000 and AS/NZS 4582:1999 
Exceeds/complies with European standard 
ETSI 300 373 and associated Amendment A 
Exceeds/complies with EMC and vibration standard IEC 945 
Complies with MIL-STD 810G for drop, dust, temperature, shock and vibration
Transmit frequency range 1.6 MHz to 30 MHz (continuous)
Receive frequency range 250 kHz to 30 MHz (continuous)*
Channel capacity Up to 30 programmable channels (simplex or semi-duplex)
Frequency resolution 10 Hz program mode
1 Hz tunable receiver
Frequency stability ±10 Hz or better than 0.3 ppm over temperature range -30°C to +70°C
Operating modes J3E (USB, LSB) - H3E (AM) - J2A (CW) - J2 (AFSK) Optional J2B (AFSK) with narrow filter
Operating temperature -30°C to +70°C humidity 95% relative, non-condensing
Supply voltage 13.8 V DC +20% / -10% (negative ground) polarity protected. Over voltage protected. 100 to 260 VAC or 11 to 16 V DC with power supply
Current consumption 470 mA standby (muted, back lighting off)
Selcall system Based on CCIR 493-4, four and six digit systems. Protocol available for free distribution. Fully compatible with other major HF manufacturers' four and six digit systems including encrypted systems
Switching speed Less than 15 mS Tx to Rx, Rx to Tx

* reduced sensitivity 250 kHz to 500 kHz

Reciever

Sensitivity -120 dBm (0.224 uV) for 10 dB SINAD - J3E Mode pre-amp on
-110 dBm (0.708 uV) for 20 dB SINAD - J3E Mode pre-amp off
Selectivity J3E -1 kHz and + 4 kHz better than 50dB
-2 kHz and +5 kHz better than 55dB
-5 kHz and +8 kHz better than 60dB
Selectivity J2B (optional) -500 Hz and +500 Hz better than 60 dB The level of an unwanted signal above the level of a wanted signal that will reduce the SINAD of the wanted signal from 20 dB SINAD to 14 dB SINAD
Blocking -20 kHz and +20 kHz better than 71 dB - The level of an unwanted signal above the level of a wanted signal that will reduce the SINAD of the wanted signal from by 6 dB or cause and output level change of 3 dB
Intermodulation Better than 89 dBµV - The level of two unwanted signals, that are within 30 kHz.of the wanted signal, above the level of a wanted signal that reduces the SINAD of the wanted signal to 20 dB
Spurious response ratio Better than 70 dB
Reciprocal mixing Better than 105 dBµV
In-band IMD Better than 34 dB
Audio output 4 W into 4 ohm at less than 2% distortion
Audio response Less than 6 dB variation from 350 Hz 
to 2700 Hz.
Input protection Better than 30 V RMS from a 50 Ohm source

Transmitter

RF output power 125 W PEP voice ±1.5dB
or 30 W PEP voice ±1.5dB
or 10 W PEP voice ±1.5dB
Duty cycle 100% two-tone input signal with fan option
Intermodulation Products better than -31 dB below PEP (25 dB below two tone peak)
Audio frequency response Less than 6 dB variation 350 Hz to 2750 Hz
Current consumption Voice average less than 9 Amps typical 
Two tone less than 12 Amps typical

 

Read 1526 times

Manager Log In

Downloadable Brochure

Our Partners

3roam-logo-tagline-250x119  barett  rain  adcon